{"id":3615,"date":"2025-07-23T12:59:22","date_gmt":"2025-07-23T10:59:22","guid":{"rendered":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/?p=3615"},"modified":"2025-07-23T12:59:23","modified_gmt":"2025-07-23T10:59:23","slug":"science-x-technology-our-research-infrastructure","status":"publish","type":"post","link":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/","title":{"rendered":"Science x Technology: Our Research Infrastructure"},"content":{"rendered":"\n<p>Wearables for Parkinson&#8217;s patients, a textile-integrated ECG for continuous monitoring, and contactless driver state recognition \u2013 just to name a few innovative solutions that have only been made possible through thorough studies and the right research infrastructure. As an application-oriented research institute, we are very fortunate to have a variety of laboratories and tools designed to meet diverse needs, customized for each study and unique product developments.<\/p>\n\n\n\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Multimodal_data_acquisition_Measuring_psycho-physiological_reactions\" >Multimodal data acquisition: Measuring psycho-physiological reactions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Psychophysiology_Lab\" >Psychophysiology Lab<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Driving_simulator\" >Driving simulator<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Advanced_Sports_Performance_and_Biomechanics_Lab\" >Advanced Sports Performance and Biomechanics Lab<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Physiological_data_acquisition_with_maphera%C2%AE_Plug_research\" >Physiological data acquisition with maphera\u00ae: Plug &amp; research<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Smart_Chair_Textile-integrated_Motion_Sensing\" >Smart Chair &amp; Textile-integrated Motion Sensing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Cinema_Lab\" >Cinema Lab<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Hardware_Lab\" >Hardware Lab<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Clinical_Settings_Infrastructure_at_the_Center_for_Sensor_Technology_and_Digital_Medicine\" >Clinical Settings: Infrastructure at the Center for Sensor Technology and Digital Medicine<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#Deep_Learning_Infrastructure\" >Deep Learning Infrastructure<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Multimodal_data_acquisition_Measuring_psycho-physiological_reactions\"><\/span>Multimodal data acquisition: Measuring psycho-physiological reactions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>What makes our institute&#8217;s infrastructure stand out is not just the range of modalities and signals we can measure, but also the flexibility to do so in different, adaptable settings, depending on the specific application and research goals.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Psychophysiology_Lab\"><\/span><a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/affective-computing\/probandenstudien.html\">Psychophysiology Lab <\/a><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Our psycho-physiological lab is designed for the acquisition of high-quality multimodal data. Central to our lab is the exposure cabin, which provides a controlled environment for synchronized data collection, unaffected by environmental influences. All equipment in the lab is designed to integrate specific measurement modalities, allowing us to tailor each setup to the unique requirements of every study.<\/p>\n\n\n\n<div class=\"wp-block-media-text alignfull is-stacked-on-mobile is-image-fill-element has-background has-normal-font-size\" style=\"background-color:#f1f1f1;grid-template-columns:55% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"683\" height=\"1024\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-683x1024.png\" alt=\"\" class=\"wp-image-1706 size-full\" style=\"object-position:50% 50%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-683x1024.png 683w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-200x300.png 200w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-768x1152.png 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-1024x1536.png 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-1365x2048.png 1365w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-370x555.png 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-270x405.png 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-570x855.png 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web-740x1110.png 740w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/01\/Arousalstudie_ExpoBox_ambient_red-2_web.png 2048w\" sizes=\"(max-width: 683px) 100vw, 683px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><\/p>\n\n\n\n<p><strong>Exposure Cabin<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-normal-font-size\">\n<li>360\u00b0 analysis of psycho-physiological reactions in a controlled environment with, e.g., defined light and noise environment<\/li>\n\n\n\n<li>Multimodal data acquisition and easy data synchronization<\/li>\n\n\n\n<li>Flexible modality setup, unaffected by environmental influences, including wearables and extensive sensor and camera equipment<\/li>\n\n\n\n<li>Individual adaptation of the experimental setup, <br>e.g., selection of modalities<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-gridlove-highlight-bg-background-color has-background wp-element-button\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/acquiring-multimodal-data-in-the-emotionai-box\/\" style=\"border-radius:10px\">Learn more<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"has-gridlove-bg-color has-text-color has-link-color wp-elements-c29acea8df43cb17ac4ecc7969acd9b7\"><\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>Furthermore, our psychophysiological laboratory is equipped with the following resources:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Video Monitoring System<\/strong>: Captures behavioral indicators and affective states for comprehensive analysis.<\/li>\n\n\n\n<li><strong>BIOPAC System<\/strong>: Measures ECG, respiration, oximetry, EEG, EMG, and skin temperature for detailed physiological monitoring.<\/li>\n\n\n\n<li><strong>AntNeuro EEG<\/strong>: Offers high-resolution brain activity monitoring for in-depth neurological assessments.<\/li>\n\n\n\n<li><strong>Tobii Eye Tracker<\/strong>: Captures information about the eyes, such as gaze, pupil size and saccades, to infer cognitive and emotional states.<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text alignfull has-media-on-the-right is-stacked-on-mobile is-image-fill-element has-background\" style=\"background-color:#f1f1f1;grid-template-columns:auto 48%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Driving_simulator\"><\/span>Driving simulator<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Driving simulators enable easy and fast data collection during driving tasks and traffic scenarios. What sets our driving simulators apart is their compatibility with any technologies used in our exposure cabin, making them ideal for multimodal biosignal acquisition and gathering insights on driving behavior, driver states, well-being, and cognitive load (stress).<\/p>\n\n\n\n<p>The driving simulators on-premise and at the <a href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/?p=3615&amp;preview=true&amp;_thumbnail_id=4195#Clinical_Settings_Infrastructure_at_the_Center_for_Sensor_Technology_and_Digital_Medicine\">Center for Sensor Technology and Digital Medicine<\/a> at Universit\u00e4tsklinikum Erlangen offer customizable modality setup of the driving simulator.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2f0dc101 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-gridlove-bg-color has-gridlove-highlight-bg-background-color has-text-color has-background has-link-color wp-element-button\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/driving-simulator\/\" style=\"border-radius:10px\">Learn more<\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1024\" height=\"678\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-1024x678.jpg\" alt=\"cognitive load assessment in the driving simulator\" class=\"wp-image-4034 size-full\" style=\"object-position:73% 49%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-1024x678.jpg 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-300x199.jpg 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-768x509.jpg 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-1536x1017.jpg 1536w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-2048x1356.jpg 2048w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-370x245.jpg 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-270x179.jpg 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-570x377.jpg 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Affective_Sensing_10_2020-2-740x490.jpg 740w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Advanced_Sports_Performance_and_Biomechanics_Lab\"><\/span>Advanced Sports Performance and Biomechanics Lab<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The Sports Performance and Biomechanics Lab specializes in comprehensive assessments of athletic performances and physical activity. Our state-of-the-art equipment allows for flexible setups and advanced monitoring technologies to gather detailed physiological and biomechanical data:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Gym Setup<\/strong>: Fully equipped facilities for diverse sports and exercise testing<\/li>\n\n\n\n<li><strong>Ergometer and Track<\/strong>: Standard equipment for controlled cardiovascular and endurance assessments.<\/li>\n\n\n\n<li><strong>BIOPAC System<\/strong>: Monitors ECG, respiration, oximetry, EEG, EMG, and skin temperature for thorough physiological analysis.<\/li>\n\n\n\n<li><strong>Wireless BIOPAC System<\/strong>: Offers mobile monitoring capabilities, ideal for field and in-lab scenarios.<\/li>\n\n\n\n<li><strong>XSens Cameras and Systems<\/strong>: Advanced biomechanical sensing using MVN Link, MVN Awinda 2, and pressure mapping for comprehensive motion capture and analysis..<\/li>\n\n\n\n<li><strong>Mobile ECG (Holter)<\/strong>: Includes BTL Flexi 12, BTL Holter 08, and CardioSecure for continuous heart monitoring.<\/li>\n\n\n\n<li><strong>Smart Textiles<\/strong>: Integrates ECG and respiration monitoring directly into sportswear for seamless data collection.<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text alignfull is-stacked-on-mobile is-image-fill-element has-background\" style=\"background-color:#f1f1f1;grid-template-columns:39% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1024\" height=\"678\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-1024x678.jpg\" alt=\"CARDIOTextil is worn by a test subject\" class=\"wp-image-2906 size-full\" style=\"object-position:50% 50%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-1024x678.jpg 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-300x199.jpg 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-768x509.jpg 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-1536x1017.jpg 1536w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-2048x1356.jpg 2048w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-370x245.jpg 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-270x179.jpg 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-570x378.jpg 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Holster_angelegt_cFraunhoferIIS-740x490.jpg 740w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><\/p>\n\n\n\n<p><strong>CardioTEXTIL<\/strong><br><strong><br><\/strong>CardioTEXTIL is a mobile multi-channel ECG that aids in the early detection of cardiac arrhythmias. Its textile-based dry electrodes enable comfortable, continuous monitoring for days, weeks, or even months \u2013 with medical-grade quality. <\/p>\n\n\n\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2f0dc101 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-gridlove-bg-color has-gridlove-highlight-bg-background-color has-text-color has-background has-link-color wp-element-button\" href=\"https:\/\/www.iis.fraunhofer.de\/en\/ff\/sse\/health\/medical-sensors-and-analytics\/prod\/cardiotextil.html\" style=\"border-radius:10px\">Learn more<\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>In addition, we offer expert support with scientific and technical consulting, bringing in our expertise in both electrophysiological signals and biomechanics, to optimize study design and data analysis.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text alignfull has-media-on-the-right is-stacked-on-mobile is-image-fill-element has-background\" style=\"background-color:#f1f1f1;grid-template-columns:auto 46%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Physiological_data_acquisition_with_maphera%C2%AE_Plug_research\"><\/span>Physiological data acquisition with maphera<sup>\u00ae<\/sup>: Plug &amp; research<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Fraunhofer maphera<sup>\u00ae<\/sup> is the one-for-all solution for the location-independent acquisition of high-quality multimodal physiological data. This portable, wireless sensor platform seamlessly integrates biomedical sensors, including ready-to-use wearables or custom sensors. The <a href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/clock-drifts-synchronization-in-wireless-sensor-networks\/\">highly synchronized sensor network<\/a> allows exceptional subject mobility while ensuring superior physiological signal quality and data consistency.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2f0dc101 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-gridlove-bg-color has-gridlove-highlight-bg-background-color has-text-color has-background has-link-color wp-element-button\" href=\"http:\/\/www.maphera.com\" style=\"border-radius:10px\">Learn more<\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1024\" height=\"730\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-1024x730.jpg\" alt=\"\" class=\"wp-image-4455 size-full\" style=\"object-position:94% 54%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-1024x730.jpg 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-300x214.jpg 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-768x547.jpg 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-1536x1095.jpg 1536w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-2048x1460.jpg 2048w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-370x264.jpg 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-270x192.jpg 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-570x406.jpg 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/07\/16_Capture0026-NEF-BA-2-740x527.jpg 740w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Smart_Chair_Textile-integrated_Motion_Sensing\"><\/span>Smart Chair &amp; Textile-integrated Motion Sensing<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Capacitive motion sensors are integrated into the <a href=\"https:\/\/www.iis.fraunhofer.de\/en\/ff\/sse\/health\/medical-sensors-and-analytics\/textilintegrierte-bewegungssensorik.html\">seating surface and backrest<\/a> of vehicle seats, chairs, or into lying surfaces combine inconspicuous sensor technology for capturing body movements with robust algorithms for mapping and interpreting movement. The low height of the sensors (approx. 0.5 mm) allows natural comfort, while their narrow design ensures that seating and lying surfaces remain breathable. The Smart Chair technology demonstrator was developed by Daimler Research and features Fraunhofer IIS capacitive sensor technology.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-5f1ce0a9 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25\"><a class=\"wp-block-button__link has-gridlove-highlight-bg-background-color has-background has-text-align-center wp-element-button\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/medical-sensing\/#Touch-sensitive_textile_surfaces_Automotive_health\" style=\"border-radius:10px\">Learn more<\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-gallery aligncenter has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-style-default\"><img decoding=\"async\" width=\"951\" height=\"1024\" data-id=\"2907\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-951x1024.png\" alt=\"Mobilization Seat with integrated sensors\" class=\"wp-image-2907\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-951x1024.png 951w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-279x300.png 279w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-768x827.png 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-1426x1536.png 1426w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-1901x2048.png 1901w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-370x399.png 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-270x291.png 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-570x614.png 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller-740x797.png 740w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Sensoren-im-Sitz_Daimler_cFraunhofer-IISBianca-Moller.png 2048w\" sizes=\"(max-width: 951px) 100vw, 951px\" \/><figcaption class=\"wp-element-caption\">Mobilization Seat (\u00a9Fraunhofer IIS \/ Bianco M\u00f6ller)<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" data-id=\"2908\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-1024x683.png\" alt=\"two hands are holding the textile integrated sensors of the Mobilization Seat\" class=\"wp-image-2908\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-1024x683.png 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-300x200.png 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-768x512.png 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-1536x1024.png 1536w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-370x247.png 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-270x180.png 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-570x380.png 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller-740x493.png 740w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/msa_sensorik_im_sitz_cFraunhofer-IISBianca-Moller.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Textile-integrated sensors (\u00a9Fraunhofer IIS \/ Bianco M\u00f6ller)<\/figcaption><\/figure>\n<\/figure>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile is-image-fill-element has-background has-normal-font-size\" style=\"background-color:#f1f1f1;grid-template-columns:auto 54%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cinema_Lab\"><\/span>Cinema Lab<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"has-normal-font-size\">The cinema on our premises is not only well-equipped to showcase innovations from Fraunhofer IIS\u2019 Audio and Media Technologies division, but it can also be configured for biosignal measurements. It essentially works like a large exposure cabin, allowing multiple test subjects to experience immersive study situtations simultaneously and consistently. 15 seats can be outfitted with BIOPACs to monitor ECG, respiration, oximetry, EEG, EMG, and skin temperature for detailed physiological monitoring. Cameras below the cinema screen are integrated for camera-based analysis.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-51f7783f wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75\"><a class=\"wp-block-button__link has-gridlove-highlight-bg-background-color has-background has-text-align-center wp-element-button\" href=\"https:\/\/www.iis.fraunhofer.de\/en\/send-mail?l=en&amp;m=1.8748668c6fd8a6ac3a2caa07f33afeaa&amp;k=43687269737469616e204dc3bc6e7a656e6d61796572&amp;r=2f656e2f66662f7373652f6865616c74682e68746d6c\" style=\"border-radius:10px\">gET IN tOUCH TO Learn More<\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1024\" height=\"682\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-1024x682.png\" alt=\"Cinema with integrated biopacs \" class=\"wp-image-3656 size-full\" style=\"object-position:50% 50%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-1024x682.png 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-300x200.png 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-768x511.png 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-1536x1022.png 1536w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-370x246.png 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-270x180.png 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-570x379.png 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis-740x492.png 740w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/kinosaal_iis.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hardware_Lab\"><\/span>Hardware Lab<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Our hardware lab is the linchpin during the development, assembly, and testing of embedded systems. Its setup offers exceptional flexibility for fast prototyping, allowing us to efficiently iterate designs and test new concepts, significantly accelerating the development process.<\/p>\n\n\n\n<p>The hardware laboratory is equipped with<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Soldering Workstations, soldering oven, and rework station (ERSA PL550A)<\/li>\n\n\n\n<li>Pick &amp; place machine (fully automatic SMD machine) for prototypes and small series production<\/li>\n\n\n\n<li>3D printer: SLA (Formlabs 3) and FFF\/FDM (Prusa Mk3s und Mk3s+)<\/li>\n\n\n\n<li>Impedance analyzers (MFIA, DropSens) &amp; Potentiostats (Biologic VSP-300)<\/li>\n\n\n\n<li>Keithley 4200A-SCS parameter analyzer (current-voltage (I-V), capacitance-voltage (C-V) and pulse characteristics)<\/li>\n\n\n\n<li>Microscopes (Vision Manis Elite-Cam HD, Vision EvoCam II)<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Clinical_Settings_Infrastructure_at_the_Center_for_Sensor_Technology_and_Digital_Medicine\"><\/span>Clinical Settings: Infrastructure at the Center for Sensor Technology and Digital Medicine<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The <a href=\"https:\/\/www.iis.fraunhofer.de\/en\/ff\/sse\/health\/zentrum-sensorik-medizin.html\">Center for Sensor Technology and Digital Medicine<\/a>, established by Fraunhofer IIS in collaboration with Universit\u00e4tsklinikum Erlangen and Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg (FAU), offers a unique infrastructure and reference systems for developing, integrating, and validating innovative health technologies. Located at the premises of Universit\u00e4tsklinikum Erlangen, our specially equipped laboratories facilitate independent testing and implementation of patient-specific therapies, digital health applications, medical diagnostics with wearables, and robotic nursing systems in a clinical setting.<\/p>\n\n\n\n<div class=\"wp-block-media-text alignfull is-stacked-on-mobile is-image-fill-element has-background\" style=\"background-color:#f1f1f1;grid-template-columns:39% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1024\" height=\"883\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-1024x883.jpg\" alt=\"\" class=\"wp-image-4109 size-full\" style=\"object-position:35% 54%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-1024x883.jpg 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-300x259.jpg 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-768x662.jpg 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-1536x1324.jpg 1536w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-2048x1766.jpg 2048w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-370x319.jpg 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-270x233.jpg 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-570x491.jpg 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2024\/12\/Capture0028-3-740x638.jpg 740w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><strong><a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/health\/cic-ganganalyselabor.html\">Motion Lab<\/a><\/strong><br><a href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/parkinson-movement-analysis\/\">The gait analysis lab <\/a>is equipped with a state-of-the-art 3D-Motion Capture System, 12 infrared cameras, and 2 force plates. This setup allows us to support patient-centered therapies and validate new sensor technologies by objectively analyzing movement patterns.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignfull is-stacked-on-mobile is-image-fill-element has-background\" style=\"background-color:#f1f1f1;grid-template-columns:39% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1024\" height=\"767\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-1024x767.jpg\" alt=\"\" class=\"wp-image-4113 size-full\" style=\"object-position:52% 36%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-1024x767.jpg 1024w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-300x225.jpg 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-768x575.jpg 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-1536x1151.jpg 1536w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-2048x1535.jpg 2048w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-370x277.jpg 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-270x202.jpg 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-570x427.jpg 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-740x554.jpg 740w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Capture0097-80x60.jpg 80w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/affective-computing\/probandenstudien.html\"><strong>Cardiology Lab<\/strong><\/a><br>The cardiology lab offers long-term and observational monitoring of a wide range cardiovascular and electrophysiological parameters with different activity profiles, including assessments for patients under minimal exertion in a patient bed and during treadmill or ergometer exercises. In addition to in-lab evaluations, we provide mobile monitoring solutions using wearables, which also include validation to ensure accuracy and reliability.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignfull is-stacked-on-mobile is-image-fill-element has-background\" style=\"background-color:#f1f1f1;grid-template-columns:39% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"359\" height=\"359\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/PPL-edited.png\" alt=\"\" class=\"wp-image-3675 size-full\" style=\"object-position:50% 50%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/PPL-edited.png 359w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/PPL-edited-300x300.png 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/PPL-edited-150x150.png 150w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/04\/PPL-edited-270x270.png 270w\" sizes=\"(max-width: 359px) 100vw, 359px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/affective-computing\/probandenstudien.html\"><strong>Physiology Lab&nbsp;<\/strong><br><\/a>Our lab specializes in the objective recognition, interpretation, and processing of human affects. We offer advanced networked sensor solutions, emotion-adaptive technologies, and perception-based user interfaces tailored to meet specific customer needs. The multimodal approach can incorporate <br>various modalities, including infrared, eye tracking, <br>ECG, respiratory analysis, and EMG, to thoroughly capture psycho-physiological data.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignfull is-stacked-on-mobile is-image-fill-element has-background\" style=\"background-color:#f1f1f1;grid-template-columns:39% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1000\" height=\"500\" src=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262.jpg\" alt=\"\" class=\"wp-image-915 size-full\" style=\"object-position:49% 59%\" srcset=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262.jpg 1000w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262-300x150.jpg 300w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262-768x384.jpg 768w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262-370x185.jpg 370w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262-270x135.jpg 270w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262-570x285.jpg 570w, https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/iStock-927809262-740x370.jpg 740w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/affective-computing\/probandenstudien.html\"><\/a><strong><a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/health\/mobile-health-lab\/managementsystem-klinische-studien.html\">Medical Data Lab<\/a><\/strong><a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/affective-computing\/probandenstudien.html\"><br><\/a>In our Medical Data Lab, we develop solutions and technologies for digital patient and study management as well as solutions for interoperable interfaces and data models using international standards (FHIR<sup>\u00ae<\/sup>, SnomedCT, LOINC, &#8230;). Our customizable study management system <a href=\"https:\/\/www.iis.fraunhofer.de\/de\/ff\/sse\/health\/mobile-health-lab\/managementsystem-klinische-studien.html\">DPM.research <\/a>streamlines data management and documentation in clinical studies, aligned with international standards and data protection regulations.<\/p>\n<\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Deep_Learning_Infrastructure\"><\/span>Deep Learning Infrastructure<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>In addition to data acquisition, our capabilities encompass the entire workflow of intelligent data analysis, including AI-based analysis and development. This process involves prototyping, integrating AI into applications, and creating high-quality datasets using bootstrapping techniques.<\/p>\n\n\n\n<p>To support this comprehensive workflow, we have established a robust on-premise infrastructure that enables the rapid development and deployment of AI solutions tailored to our customers&#8217; applications. This infrastructure facilitates efficient design iteration, concept testing, and the delivery of exceptional AI products.<\/p>\n\n\n\n<p>Our deep learning infrastructure includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Local High Performance 35 Node Cluster, 72x NVidia P100 GPU, 16x NVidia P40 GPU, 2.8 TB RAM, 4x H100 GPUs, 1.5TB and AMD EPYC 9654 CPUs<\/li>\n\n\n\n<li>Several single-GPU Nvidia RTX 3090\/4090 and multi-GPUA5000\/A8000 workstations.<\/li>\n\n\n\n<li>RRZE-hosted IIS-owned 3x4xH100 SXM5 Nodes with general access to the NHR compute cluster.<\/li>\n<\/ul>\n\n\n\n<p>As a basis for our AI-based algorithms, we have created a multimodal database for the detection of cognitive overload: <a href=\"https:\/\/www.iis.fraunhofer.de\/en\/ff\/sse\/sse-automotive\/multimodal-data-set-for-mental-overload-adabase.html\">ADABase<\/a> (<em>Autonomous Driving Cognitive Load Assessment Database<\/em>). <\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-gridlove-highlight-bg-background-color has-background wp-element-button\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/cognitive-load-in-autonomous-driving\/\" style=\"border-radius:10px\">Learn more<\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-gridlove-highlight-bg-background-color has-background wp-element-button\" href=\"https:\/\/adabase-dataset.github.io\/\" style=\"border-radius:10px\">gET ACCESS TO adabASE<\/a><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Image Copyright: Fraunhofer IIS \/ Bianca M\u00f6ller &amp; Paul Pulkert<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Wearables for Parkinson&#8217;s patients, a textile-integrated ECG for continuous monitoring, and contactless driver state recognition \u2013 just to name a few innovative solutions that have only been made possible through thorough studies and the right research infrastructure. As an application-oriented research institute, we are very fortunate to have a variety of laboratories and tools designed [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":4195,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[39,98],"tags":[],"coauthors":[51,75],"class_list":["post-3615","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-digital-health","category-infrastructure"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Science x Technology: Our Research Infrastructure - SMART SENSING insights<\/title>\n<meta name=\"description\" content=\"Research needs the right infrastructure. At Fraunhofer IIS we provide various tools and labs to meet diverse needs. Have a look.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Science x Technology: Our Research Infrastructure - SMART SENSING insights\" \/>\n<meta property=\"og:description\" content=\"Research needs the right infrastructure. At Fraunhofer IIS we provide various tools and labs to meet diverse needs. Have a look.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/\" \/>\n<meta property=\"og:site_name\" content=\"SMART SENSING insights\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/FraunhoferIIS\" \/>\n<meta property=\"article:published_time\" content=\"2025-07-23T10:59:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-23T10:59:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Hardwarelabor-CardiaTool-1024x683.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Grit Nickel, Anna Chiwona\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Grit Nickel, Anna Chiwona\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/\"},\"author\":{\"name\":\"Grit Nickel\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#\\\/schema\\\/person\\\/fc55925f8da111629c277bcedf848c5e\"},\"headline\":\"Science x Technology: Our Research Infrastructure\",\"datePublished\":\"2025-07-23T10:59:22+00:00\",\"dateModified\":\"2025-07-23T10:59:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/\"},\"wordCount\":1404,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Hardwarelabor-CardiaTool.jpg\",\"articleSection\":[\"Digital Health\",\"Infrastructure\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/\",\"url\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/\",\"name\":\"Science x Technology: Our Research Infrastructure - SMART SENSING insights\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Hardwarelabor-CardiaTool.jpg\",\"datePublished\":\"2025-07-23T10:59:22+00:00\",\"dateModified\":\"2025-07-23T10:59:23+00:00\",\"description\":\"Research needs the right infrastructure. At Fraunhofer IIS we provide various tools and labs to meet diverse needs. Have a look.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#primaryimage\",\"url\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Hardwarelabor-CardiaTool.jpg\",\"contentUrl\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Hardwarelabor-CardiaTool.jpg\",\"width\":8256,\"height\":5504,\"caption\":\"Fraunhofer IIS research infrastructure leaves no wishes unfulfilled - like in this image the scientist working in the hardware lab\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/science-x-technology-our-research-infrastructure\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Science x Technology: Our Research Infrastructure\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#website\",\"url\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/\",\"name\":\"SMART SENSING insights\",\"description\":\"learn more about our focus research areas sensor technology, electronics, and artificial intelligence\",\"publisher\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#organization\",\"name\":\"Fraunhofer IIS\",\"url\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/Fraunhofer-IIS-1.png\",\"contentUrl\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/Fraunhofer-IIS-1.png\",\"width\":826,\"height\":299,\"caption\":\"Fraunhofer IIS\"},\"image\":{\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/FraunhoferIIS\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/fraunhofer-iis\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/#\\\/schema\\\/person\\\/fc55925f8da111629c277bcedf848c5e\",\"name\":\"Grit Nickel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/cropped-Grit_Nickel-glasowfotografie_1zu1-96x96.jpgb9e2641f671ece8d5eef3a78bdbb8b8e\",\"url\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/cropped-Grit_Nickel-glasowfotografie_1zu1-96x96.jpg\",\"contentUrl\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/cropped-Grit_Nickel-glasowfotografie_1zu1-96x96.jpg\",\"caption\":\"Grit Nickel\"},\"description\":\"Grit is a content writer at Fraunhofer IIS and a science communication specialist. She has 6+ years of experience in research and holds a PhD in German linguistics.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/grit-nickel\\\/\"],\"url\":\"https:\\\/\\\/websites.fraunhofer.de\\\/smart-sensing-insights\\\/author\\\/grit-nickeliis-fraunhofer-de\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Science x Technology: Our Research Infrastructure - SMART SENSING insights","description":"Research needs the right infrastructure. At Fraunhofer IIS we provide various tools and labs to meet diverse needs. Have a look.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/","og_locale":"en_US","og_type":"article","og_title":"Science x Technology: Our Research Infrastructure - SMART SENSING insights","og_description":"Research needs the right infrastructure. At Fraunhofer IIS we provide various tools and labs to meet diverse needs. Have a look.","og_url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/","og_site_name":"SMART SENSING insights","article_publisher":"https:\/\/www.facebook.com\/FraunhoferIIS","article_published_time":"2025-07-23T10:59:22+00:00","article_modified_time":"2025-07-23T10:59:23+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Hardwarelabor-CardiaTool-1024x683.jpg","type":"image\/jpeg"}],"author":"Grit Nickel, Anna Chiwona","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Grit Nickel, Anna Chiwona","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#article","isPartOf":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/"},"author":{"name":"Grit Nickel","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#\/schema\/person\/fc55925f8da111629c277bcedf848c5e"},"headline":"Science x Technology: Our Research Infrastructure","datePublished":"2025-07-23T10:59:22+00:00","dateModified":"2025-07-23T10:59:23+00:00","mainEntityOfPage":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/"},"wordCount":1404,"commentCount":0,"publisher":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#organization"},"image":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#primaryimage"},"thumbnailUrl":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Hardwarelabor-CardiaTool.jpg","articleSection":["Digital Health","Infrastructure"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/","url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/","name":"Science x Technology: Our Research Infrastructure - SMART SENSING insights","isPartOf":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#website"},"primaryImageOfPage":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#primaryimage"},"image":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#primaryimage"},"thumbnailUrl":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Hardwarelabor-CardiaTool.jpg","datePublished":"2025-07-23T10:59:22+00:00","dateModified":"2025-07-23T10:59:23+00:00","description":"Research needs the right infrastructure. At Fraunhofer IIS we provide various tools and labs to meet diverse needs. Have a look.","breadcrumb":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#primaryimage","url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Hardwarelabor-CardiaTool.jpg","contentUrl":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2025\/05\/Hardwarelabor-CardiaTool.jpg","width":8256,"height":5504,"caption":"Fraunhofer IIS research infrastructure leaves no wishes unfulfilled - like in this image the scientist working in the hardware lab"},{"@type":"BreadcrumbList","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/science-x-technology-our-research-infrastructure\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/"},{"@type":"ListItem","position":2,"name":"Science x Technology: Our Research Infrastructure"}]},{"@type":"WebSite","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#website","url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/","name":"SMART SENSING insights","description":"learn more about our focus research areas sensor technology, electronics, and artificial intelligence","publisher":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#organization","name":"Fraunhofer IIS","url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#\/schema\/logo\/image\/","url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/06\/Fraunhofer-IIS-1.png","contentUrl":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/06\/Fraunhofer-IIS-1.png","width":826,"height":299,"caption":"Fraunhofer IIS"},"image":{"@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/FraunhoferIIS","https:\/\/www.linkedin.com\/company\/fraunhofer-iis"]},{"@type":"Person","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/#\/schema\/person\/fc55925f8da111629c277bcedf848c5e","name":"Grit Nickel","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/cropped-Grit_Nickel-glasowfotografie_1zu1-96x96.jpgb9e2641f671ece8d5eef3a78bdbb8b8e","url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/cropped-Grit_Nickel-glasowfotografie_1zu1-96x96.jpg","contentUrl":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-content\/uploads\/2023\/08\/cropped-Grit_Nickel-glasowfotografie_1zu1-96x96.jpg","caption":"Grit Nickel"},"description":"Grit is a content writer at Fraunhofer IIS and a science communication specialist. She has 6+ years of experience in research and holds a PhD in German linguistics.","sameAs":["https:\/\/www.linkedin.com\/in\/grit-nickel\/"],"url":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/author\/grit-nickeliis-fraunhofer-de\/"}]}},"_links":{"self":[{"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/posts\/3615","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/comments?post=3615"}],"version-history":[{"count":126,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/posts\/3615\/revisions"}],"predecessor-version":[{"id":4817,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/posts\/3615\/revisions\/4817"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/media\/4195"}],"wp:attachment":[{"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/media?parent=3615"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/categories?post=3615"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/tags?post=3615"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/websites.fraunhofer.de\/smart-sensing-insights\/wp-json\/wp\/v2\/coauthors?post=3615"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}