Technical aspects in detail: Unterschied zwischen den Versionen

Aus Cometh-Wiki
Zur Navigation springen Zur Suche springen
Zeile 15: Zeile 15:
 
  | since 1996 over 100 units in operation
 
  | since 1996 over 100 units in operation
 
  |-
 
  |-
−
  | [[Boilers / Burners]]
+
  | [[Boilers / Burners - monovalent]]
 
  | (20) 25 - 100
 
  | (20) 25 - 100
 
  | proved and tested
 
  | proved and tested
Zeile 21: Zeile 21:
 
  | since 1980th
 
  | since 1980th
 
  |-
 
  |-
−
  | [[Boilers / Burners]]
+
  | [[Boilers / Burners - additional]]
 
  | (20) 25 - 100
 
  | (20) 25 - 100
 
  | proved and tested
 
  | proved and tested
 
  | Heat, emission reduction
 
  | Heat, emission reduction
−
  | since 1980th
+
  | since 1900 on mines
 +
|-
 +
| [[CMM flaring]]
 +
| 20 - 100
 +
| proved
 +
| Emission reduction
 +
| used on landfills
 +
|-
 +
| [[Liquified Natural Gas - LNG]]
 +
| 50 - 100
 +
| tested
 +
| LNG, emission reduction
 +
| 660 Mio. m³ in 2006 (US-market)
 +
|-
 +
| [[VAM utilisation]]
 +
| 0,2 - 1,2
 +
| demonstration
 +
| -
 +
| some are in operation
 +
|-
 +
| [[Gas turbines / mikro turbines]]
 +
| 40 - 100
 +
| demonstration
 +
| - 
 +
| -
 +
|-
 +
| [[Fuel Cells]]
 +
| 30 - 100
 +
| pilot
 +
| -
 +
| -
 +
|}

Version vom 25. September 2011, 13:24 Uhr

Depending on the compostion and the amount of CMM (data delivered by a gas prognosis) and the kind of the mine (abandoned or acticve mine) different types of utilisation are possible. An overview of proved and tested utilisation technologies depending on the CH4 - content are shown in the table below:

Technology CH4 [%] Status Products Remarks
Gas engines (25) 30 - 100 proved and tested Power, heat, emission reduction since 1996 over 100 units in operation
Boilers / Burners - monovalent (20) 25 - 100 proved and tested Heat, emission reduction since 1980th
Boilers / Burners - additional (20) 25 - 100 proved and tested Heat, emission reduction since 1900 on mines
CMM flaring 20 - 100 proved Emission reduction used on landfills
Liquified Natural Gas - LNG 50 - 100 tested LNG, emission reduction 660 Mio. m³ in 2006 (US-market)
VAM utilisation 0,2 - 1,2 demonstration - some are in operation
Gas turbines / mikro turbines 40 - 100 demonstration - -
Fuel Cells 30 - 100 pilot - -